HDS Function
DTC (PGM-FI)
Clear DTC (PGM-FI)
PGM-FI > Data List
Data List
| Signal | Current conditions (Values) | Current conditions (Unit) |
|---|---|---|
| ECT Sensor 1 Voltage |
Inspection
ECT Sensor 1 Inspection
NOTE:
Since there is no direct method to test the component itself, troubleshooting is performed on the related components.
Test Procedure
Unit output voltage inspection
- Preparation
- ECT sensor 1 connector (2P) : disconnected
- Procedure
- Turn the vehicle to the ON mode.
- Confirm the HDS [ ECT Sensor 1 Voltage ].
- Normal Conditions
- HDS [ ECT Sensor 1 Voltage ] value is more than 0.08 V .
Results
- If it is normal, there is a problem with ECT sensor 1.
- If it is abnormal, there is a problem with other related components.
TW Shorted Wire Inspection
Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.
Test Procedure
- Preparation
- PCM connector E (80P) : disconnected
- ECT sensor 1 connector (2P) : disconnected
- Procedure
- Perform the inspection according to the following table.
Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
(Disconnected) ECT sensor 1 connector (2P) female terminals IG Mode Normal Conditions TW shorted to ground inspection OFF There is more than 1 MOhm - Perform the inspection according to the following table.
Results
- If abnormal, there is a problem in the circuit.
PCM Inspection
Test Procedure
- If the other inspection item (s) indicated a normal condition, then it is determined that the remaining PCM is the cause.
Results
- There is a problem with the PCM.