HDS Function
DTC (PGM-FI)
Clear DTC (PGM-FI)
PGM-FI > Data List
Data List
| Signal | Current conditions (Values) | Current conditions (Unit) |
|---|---|---|
| IAT Sensor (2) |
Inspection
Connector Visual Inspection
Test Procedure
- Procedure
- Check the connectors for a secure connection or for loose terminals at the following components:
- ECT sensor 1
- ECT sensor 2
- MAF sensor/IAT sensor 1
- IAT sensor 2
- Check the connectors for a secure connection or for loose terminals at the following components:
- Normal Conditions
- Conditions at the connections and terminals are OK.
Results
- If it is abnormal, there is a problem with the connections or terminals.
IAT Sensor 2 Inspection (Low Temperature)
Test Procedure
- Preparation
- IAT sensor 2: removed and cooled to the ambient temperature
- Procedure
- Write down the ambient temperature.
- Connect the IAT sensor 2 connector (2P), but do not install IAT sensor 2.
- Turn the vehicle to the ON mode.
- Quickly look at the HDS [ IAT Sensor (2) ] value.
- Compare the HDS [ IAT Sensor (2) ] value to the ambient temperature.
- Normal Conditions
- The difference between the HDS [ IAT Sensor (2) ] value and the ambient temperature is less than 5.4 deg.F (3 deg.C) .
Results
- If it is abnormal, there is a problem with IAT sensor 2.
IAT Sensor 2 Inspection (High Temperature)
Test Procedure
- Preparation
- IAT sensor 2: removed
- Procedure
- Connect the IAT sensor 2 connector (2P), but do not install IAT sensor 2.
- Turn the vehicle to the ON mode.
- Heat IAT sensor 2 with heat gun for a few seconds.NOTE:
Do not apply the heat longer than a few seconds or you will damage the sensor.
- Confirm the HDS [ IAT Sensor (2) ].
- Normal Conditions
- HDS [ IAT Sensor (2) ] value is more than 76 deg. F (42 deg. C) .
Results
- If it is abnormal, there is a problem with IAT sensor 2.