HDS Function
DTC (PGM-FI)
Clear DTC (PGM-FI)
PGM-FI > Function Test > TC BYPASS CONTROL SOL.V. TEST
TC BYPASS CONTROL SOL.V. TEST
PGM-FI > Data List
Data List
Inspection
Turbocharger Bypass Control Solenoid Valve Component Inspection
Test Procedure
- Preparation
- Turbocharger bypass control solenoid valve connector (2P) : disconnected
- Procedure
- Perform the inspection according to the following table.
(Disconnected) Turbocharger bypass control solenoid valve connector (2P) male terminals IG Mode Normal Conditions Valve internal circuit inspection OFF About 30 - 34 Ohm (at room temperature)
Results
- If it is abnormal, there is a problem with turbocharger bypass control solenoid valve.
IG1 (ABV) Circuit Inspection
Test Procedure
- Preparation
- Turbocharger bypass control solenoid valve connector (2P) : disconnected
- Procedure
- Perform the inspection according to the following table.
(Disconnected) Turbocharger bypass control solenoid valve connector (2P) female terminals IG Mode Normal Conditions IG1 (ABV) circuit inspection ON 12 V battery voltage [ circuit type 1 ]
Results
- If abnormal, there is a problem in the circuit.
If the power supply inspection of the above table showed abnormally, do the additional Power Supply Inspection , to locate the failure.
ABV Shorted Wire Inspection
Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.
Test Procedure
- Preparation
- Turbocharger bypass control solenoid valve connector (2P) : disconnected
- PCM connector E (80P) : disconnected
- Procedure
- Perform the inspection according to the following table.
Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
(Disconnected) Turbocharger bypass control solenoid valve connector (2P) female terminals IG Mode Normal Conditions ABV shorted to ground inspection OFF There is more than 1 MOhm - Perform the inspection according to the following table.
Results
- If abnormal, there is a problem in the circuit.
PCM Inspection
Test Procedure
- If the other inspection item (s) indicated a normal condition, then it is determined that the remaining PCM is the cause.
Results
- There is a problem with the PCM.