HDS Function
DTC (PGM-FI)
Clear DTC (PGM-FI)
PGM-FI > Function Test > VTC TEST > EX-VTC
EX-VTC
PGM-FI > Data List
Data List
Inspection
VTC Oil Control Solenoid Valve B Component Inspection
Test Procedure
- Preparation
- VTC oil control solenoid valve B connector (2P) : disconnected
- Procedure
- Perform the inspection according to the following table.
(Disconnected) VTC oil control solenoid valve B connector (2P) male terminals IG Mode Normal Conditions Valve internal circuit inspection OFF About 7.14 - 7.90 Ohm (at room temperature)
Results
- If abnormal, there is a problem with VTC oil control solenoid valve B.
VTC (EX), PG Circuit Inspection
Before disconnecting the PCM connector, jump the SCS line with the HDS, and wait more than 1 minute.
Test Procedure
- Preparation
- PCM connector E (80P) : disconnected
- VTC oil control solenoid valve B connector (2P) : disconnected
- Procedure
- Perform the inspection according to the following table.
(Disconnected) VTC oil control solenoid valve B connector (2P) female terminals (Disconnected) PCM connector E (80P) female terminals IG Mode Normal Conditions PG open wire inspection OFF There is less than 1 Ohm VTC (EX) open wire inspection OFF There is less than 1 Ohm
Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.VTC (EX) shorted to ground inspection OFF There is more than 1 MOhm
Results
- If abnormal, there is a problem in the circuit.
PCM Inspection
Test Procedure
- If the other inspection item (s) indicated a normal condition, then it is determined that the remaining PCM is the cause.
Results
- There is a problem with the PCM.