LEMON Manuals: Even more car manuals for everyone

Catalyst (Bank 2)

DTC P0430: Monitor ID $21: Test ID $A1

OBD Monitor ID $22 Test ID $A1 Unit and Scaling ID $0B
DTC P0430
Test Description Catalyst capability, monitored by measuring the stability of the secondary heated oxygen sensor output value.
Store Timing Normal judgment/Failure judgment
Conversion to Engineering Units Measured value: Output value (Decimal) x 0.001 (V)
The lowest limit value: Not applicable
The highest limit value: Output value (Decimal) x 0.001 (V)