MICU Input Test
WARNING: This page is about a different variant/trim than selected.
- Remove the left side kick panel (see TRIM REMOVAL/INSTALLATION - DOOR AREAS ).
- Disconnect the under-dash fuse/relay box connectors D, E, H, I, J, K, N, P and X.NOTE: All connectors are shown from wire side of female terminals.
- Inspect the connector and socket terminals to be sure they are all making good contact.
- If the terminals are bent, loose or corroded, repair them as necessary, and recheck the system.
- If the terminals look OK, go to step 4.
- With the connectors still disconnected from the under-hood fuse/relay box, make these input tests at the connector(s).
- If any test indicates a problem, find and correct the cause, then recheck the system.
- If all the input tests prove ok, go to step 5.
POSSIBLE CAUSECavity Wire Test condition Test: Desired result Possible cause if result is not obtained H9 BLK Under all conditions Check for continuity to ground.
There should be continuity.- Poor ground (G501, G601)
- An open in the wire
PI BRN Under all conditions Check for continuity to ground:
There should be continuity.- Poor ground (G502)
- An open in the wire
E9 BLK Under all conditions Check for continuity to ground:
There should be continuity.- Poor ground (G501, G601>
- An open in the wire
N22 LT BLU Under all conditions Check for continuity between terminal N22 and the climate control unit B (16P) connector terminal No. 14:
There should be continuityAn open in the wire Climate control unit B (16P) connector disconnected Check for continuity to ground:
There should be no continuity.A short to ground in the wire J4 GRN(1)
BRN/RED(2)Under all conditions Check for continuity between terminal J4 and power window master switch 23P connector terminal No. 16:
There should be continuityAn open in the wire Power window master switch 23P connector disconnected Check for continuity to ground:
There should be no continuity.A short to ground in the wire D11 BLU Under all conditions Check for continuity between terminal D11 and relay control module I (10P) connector terminal No 7.
There should be continuity.An open in the wire Relay control module I (10P) connector disconnected Check for continuity to ground:
There should be no continuity.A short to ground in the wire X27 LT GRN Under all conditions Check for continuity between terminal X27 and wiper/washer switch 8P connector terminal No. 4
There should be continuity.An open in the wire Wiper/washer switch 8P connector disconnected Check for continuity to ground:
There should be no continuity.A short to ground in the wire N28 BRN Under all conditions Check for continuity between terminal N28 and gauge assembly (30P) connector terminal No. 25:
There should be continuity.An open in the wire Gauge control module 30P connector disconnected Check for continuity to ground:
There should be no continuity.A short to ground in the wire (1) '05 model (2) '06-07 models - Reconnect the connectors to the under-dash fuse/relay box, and make sure these input tests at the appropriate connectors on the under-dash fuse/relay box.
- If any test indicates a problem, find and correct the cause, then recheck the system.
- If all the input tests prove OK, the multiplex integrated control unit must be faulty, replace the under-dash fuse/relay box assembly.
POSSIBLE CAUSECavity Wire Test condition Test: Desired result Possible cause if result is not obtained P7 ORN Under all conditions Attach to ground:
The ignition key light should come on.- Blown No. 13 (20 A) fuse in the under-hood fuse/relay box
- Blown LED
- An open in the wire
14 GRN/RED Ceiling light switch in the middle position, all doors closed Attach to ground:
The ceiling light should come on.- Blown No. 6 (7.5 A) fuse in the under-dash fuse/relay box
- Faulty ceiling light
- An open in the wire
D6
J9
X34YEL Ignition switch ON (II) Check for voltage to ground:
There should be battery voltage.- Blown No. 21 (7.5 A) fuse in the under-dash fuse/relay box
- An open in the wire
K4 GRN/WHT Under all conditions Check for voltage to ground:
There should be battery voltage.- Blown No. 27 (20 A) fuse in the under-dash fuse/relay box
- An open in the wire
X35 WHT Under all conditions Check for voltage to ground:
There should be battery voltage.- Blown No. 7 (10 A) fuse in the under-dash fuse/relay box
- An open in the wire