LEMON Manuals: Even more car manuals for everyone

Yaw Rate

"Offset" is a reference voltage or standard within the yaw rate sensor. It should indicate 1.500 to 3.500 V with the vehicle stopped.

"Sensor" indicates the voltage output from the yaw rate sensor. It should indicate 1.500 to 3.500 V with the vehicle stopped.

A "Sensor" output voltage HIGHER than that of the "Offset" voltage indicates the vehicle is turning to the RIGHT.

A "Sensor" output voltage LOWER than that of the "Offset" voltage indicates the vehicle is turning to the LEFT.

With the vehicle stopped, sitting still, with the engine idling, both the "Offset" and "Sensor" voltages should be within 0.01 V +/- of each other.

If not, replace the navigation unit.

Example:

NOTE: The vehicle is stopped, sitting still, with the engine idling.

Good 

Offset 2.517 V 

Sensor 2.517 V (0.010 V+/-) 

Bad 

Offset 2.517 V 

Sensor 2.823 V 

NOTE: Do not try to tune the yaw rate sensor unless instructed by American Honda.
Fig 1: Identifying Yaw Rate Sensor Voltage Display
G04548572Courtesy of AMERICAN HONDA MOTOR CO., INC.