LEMON Manuals: Even more car manuals for everyone

Typical Scan Tool Data

EC Ignition Relay

Display Parameters Normal Range Short to Ground Open/High Resistance Short to Voltage
Operating Conditions:  Ignition ON, engine OFF
EC Ignition Relay Circuit Status OK/Incomplete Short to GRN/Open Short to GRN/Open Short to B+
EC Ignition Relay Command ON ON ON ON
EC Ignition Relay Feedback Signal 12-12.9 V 0.0 V 0.0 V 12-12.9 V