LEMON Manuals: Even more car manuals for everyone

Secondary Vacuum Break

NOTE: Choke coil lever adjustment must be correct before performing this adjustment. This adjustment is performed using the choke angle gauge, see procedure at beginning of Adjustment.
  1. Using an outside vacuum source of at least 15 in. Hg, seat secondary vacuum break diaphragm. Plug purge bleed hole (if equipped) with masking tape. Hole is found in end of diaphragm.
  2. On vacuum delay models with air bleed, plug end cover with an accelerator pump plunger cap (2G carburetor type). Remove pump plunger cap after adjustment.
  3. Air valve rod must not keep vacuum unit from fully retracting. If necessary, bend air valve rod at air valve lever to provide clearance for proper adjustment. Adjust final air rod clearance after setting secondary vacuum break adjustment.
  4. Lightly close choke valve by pushing up on choke coil lever or vacuum break lever tang. Hold in position with a rubber band. Make sure bucking spring on diaphragm plunger (if equipped) is compressed and seated. Bubble on choke valve angle gauge should be centered with specified degree mark opposite pointer. See Fig 1.
    Fig 1: Secondary Vacuum Break Adjustment
    G09360549Courtesy of GENERAL MOTORS COMPANY

    Lightly hold choke in closed position. 

  5. To adjust, turn screw at end of vacuum diaphragm until bubble in angle gauge is centered. Remove gauge.