Choke Coil Lever
NOTE:
Choke coil cover is retained on housing with rivets to prevent tampering with factory adjustment. If necessary to remove cover, refer to DISASSEMBLY and REASSEMBLY procedures in this article. If rivets and cover are removed, a choke thermostat cover retainer kit is required for reassembly.
Place fast idle speed screw on high step of fast idle cam.
- Remove choke thermostatic cover from choke housing. Place fast idle speed screw on high step of fast idle cam. Push up on thermostatic coil tang (counterclockwise) until choke valve is fully closed.
- Insert specified drill or pin gauge in hole provided in choke housing. Lower edge of choke lever (inside housing) should just touch drill or pin gauge. See Fig 1.
- To adjust, bend choke rod at point shown in Fig 1. Reinstall choke cover and adjust.