Generator And Regulator (Except Hybrid): Specifications: Specifications
General Specifications
| Item | Specification |
|---|---|
| 1.5L EcoBoost - 150A (base) | |
| Generator pulley ratio | 2.42:1 |
| Generator pulley replaceable | Yes |
| Generator pulley type | Overrunning Alternator Decoupler (OAD) |
| Rating | 90 amps at 750 RPM (min) to 155 amps at 2, 400 RPM (max) |
| Voltage regulator type | Electronic internal with generator |
| 1.5L EcoBoost - 175A (optional) | |
| Generator pulley ratio | 2.42:1 |
| Generator pulley replaceable | Yes |
| Generator pulley type | OAD |
| Rating | 120 amps at 765 RPM (min) to 180 amps at 2, 480 RPM (max) |
| Voltage regulator type | Electronic internal with generator |
| 2.0L EcoBoost - 150A (base) | |
| Generator pulley ratio | 2.76:1 |
| Generator pulley replaceable | Yes |
| Generator pulley type | OAD |
| Rating | 90 amps at 675 RPM (min) to 160 amps at 2, 200 RPM (max) |
| Voltage regulator type | Electronic internal with generator |
| 2.0L EcoBoost - 175A (optional) | |
| Generator pulley ratio | 2.44:1 |
| Generator pulley replaceable | Yes |
| Generator pulley type | OAD |
| Rating | 120 amps at 765 RPM (min) to 180 amps at 2, 480 RPM (max) |
| Voltage regulator type | Electronic internal with generator |
| 2.0L EcoBoost - 200A (optional) | |
| Generator pulley ratio | 2.44:1 |
| Generator pulley replaceable | Yes |
| Generator pulley type | OAD |
| Rating | 130 amps at 750 RPM (min) to 200 amps at 2, 400 RPM (max) |
| Voltage regulator type | Electronic internal with generator |
| 2.7L EcoBoost - 200A | |
| Generator pulley ratio | 2.43:1 |
| Generator pulley replaceable | Yes |
| Generator pulley type | OAD |
| Rating | 130 amps at 750 RPM (min) to 200 amps at 2, 400 RPM (max) |
| Voltage regulator type | Electronic internal with generator |