LEMON Manuals: Even more car manuals for everyone

Electrical Operation

Solenoid operation:

NEUTRAL POSITION SOLENOID OPERATION CHART

Base Selector Lever Position PCM Commanded Gear Shift Solenoid TCC (VFS) NL
SSA (VFS) NL (1, 2, 3, 4) SSB (VFS) NH (3, 5, R) SSC (VFS) NL (2, 6) SSD (VFS) NH (L, R/4, 5, 6) SSE (On/Off) NC
N N Off On Off Off On Off
NC = Normally closed
NH = Normally high
NL = Normally low
Fig 1: Neutral Position Operation Diagram
G07930946Courtesy of FORD MOTOR CO.