LEMON Manuals: Even more car manuals for everyone

Heated Gas Oxygen (HEGO) Sensor Test

Disconnect oxygen sensor connector. Measure voltage between oxygen sensor wire and ground. At idle voltage reading should be 0.2-0.8 volts. Increasing engine speed increases oxygen sensor voltage and decreasing engine speed decreases oxygen sensor voltage. Replace if out of specification.