Code 42 - Fuel Always Rich

Vehicle must be at normal operating temperature. Disconnect jumper wire between ground and Self-Test trigger. Ensure power is present at choke cap, cold enrichment circuit works, and choke is off.

  1. With ignition off, disconnect thermactor air hose at pump, and vehicle harness at oxygen sensor. Connect a voltmeter between oxygen sensor and ground. Disconnect PCV hose from carburetor. Run engine at 2400 RPM for 60 seconds, then observe voltmeter.
  2. If voltage is greater than 0.5 volts, replace oxygen sensor. If voltage is less than 0.5 volts, reconnect PCV and oxygen sensor. Go to next step.
  3. Stop engine and turn ignition off. Disconnect vehicle harness from feedback motor on carburetor. Connect a known good motor (shaft fully depressed) to harness; leave original motor on carburetor. Turn ignition to "Run" position. If shaft extends, then retracts slightly, go to next step. If motor does not extend, go to step 5).
  4. Remove vacuum source at zone vacuum switches. Using a vacuum pump, apply 10-12 in. Hg vacuum. Start engine and place on high step of fast idle cam. Let engine run for 2 minutes, then force system rich by depressing CVR rod on top of carburetor. Observe test feedback motor. If shaft does not retract, disconnect motor and go to next step. If shaft retracts until flush, turn ignition off and reconnect thermactor hose. Go to step 7).
  5. With ignition off, disconnect harness connector at MCU and feedback motor. Check continuity of all wires between feedback motor connector and MCU connector. If resistance in any circuit is more than 5 ohms, repair circuit. If all are less than 5 ohms resistance, go to next step.
  6. Connect 1 lead of ohmmeter to engine ground, and test pins from feedback motor connector (except Gry/Yel wire). If resistance of each circuit is more than 1000 ohms, continue test. If resistance of any circuit is less than 1000 ohms, repair circuit.
  7. Connect 1 ohmmeter lead to feedback connector terminal 687 (Gry/Yel wire) and other ohmmeter lead to each of 4 outside terminals in turn. Measure resistance of each FBCA winding. If all resistances are 50-175 ohms at room temperature or above, replace feedback motor. If any winding is not 50-175 ohms, go to next step.
  8. With ignition off, connect ohmmeter between feedback motor case and terminal 687 (Gry/Yel wire) of motor. If resistance is less than 190,000 ohms, replace motor. If greater than 190,000 ohms, go to next step.
  9. Remove feedback motor from carburetor. Check pintle for binding or damage. Connect harness to motor and turn ignition on. Shaft should extend, then retract when ignition is turned off. If motion is uneven, or shaft rotates, replace motor. Reinstall good motor in carburetor and check vacuum lines, evaporative emission system, and crankcase for fuel dilution.
Fig 1: Fuel Always Rich Test Connections
G1262