LEMON Manuals: Even more car manuals for everyone

Damper, Vibration: Installation: Installation

WARNING: This page is about a different variant/trim than selected.
Fig 1: Installing Vibration Damper Onto Crankshaft Using Special Tool
GC0144946Courtesy of CHRYSLER GROUP, LLC
  1. Using (special tool #10387, Installer, Vibration Damper). Install the threaded rod (1) into the face of the crankshaft (3) till the face of the rod (4) bottoms out.
    Fig 2: Installing Vibration Damper
    GC0144947Courtesy of CHRYSLER GROUP, LLC
  2. Position the vibration damper (2) on the crankshaft.
  3. Using Damper Installer (1) and a deep well socket, press the damper onto the crankshaft till seated.
  4. Remove the Damper Installer tool (1) and install the crankshaft damper bolt.
    Fig 3: Installing Vibration Damper Onto Vibration Pulley
    GC0143968Courtesy of CHRYSLER GROUP, LLC
  5. Position the (special tool #10386, Holder, Vibration Damper) (2), onto the vibration pulley (3).
  6. Tighten the bolt to 176 N.m (129 ft. lbs.).
    Fig 4: Cooling Fan Motor Assembly
    GC0145660Courtesy of CHRYSLER GROUP, LLC
  7. Install the cooling fan module. Refer to FAN, COOLING, INSTALLATION .
    Fig 5: Identifying Accessory Drive Belt, Tensioner & Pulleys
    GC0144483Courtesy of CHRYSLER GROUP, LLC
  8. Install serpentine belt (1). Refer to BELT, SERPENTINE, INSTALLATION .
    Fig 6: Upper Radiator Hose Clamp & Retainer
    GC0145666Courtesy of CHRYSLER GROUP, LLC
  9. Position the upper radiator hose and secure retainer (2) at the fan shroud.
  10. Install the upper radiator hose at the thermostat housing and secure hose clamp (1).
  11. Install the air cleaner resonator support bracket at the water pump.
    Fig 7: Intake Air Temperature (IAT) Sensor, Air Cleaner Housing, Resonator Retaining Bolt & Hose Clamp
    GC0144403Courtesy of CHRYSLER GROUP, LLC
  12. Connect the resonator hose at the throttle body and tighten clamp (4) to 5 N.m (44 in. lbs.).
  13. Install the resonator retaining bolt (3) and tighten to 5 N.m (44 in. lbs.).
  14. Connect the clean air hose at the air cleaner housing and tighten clamp (2) to 5 N.m (44 in. lbs.).
  15. Connect the electrical connector at the Intake Air Temperature (IAT) sensor (1).
  16. Refill the cooling system. Refer to STANDARD PROCEDURE .
  17. Connect the negative battery cable.