Instrument Cluster Test 5A - Hard Wired Warning Light Problems
NOTE:
Perform INSTRUMENT CLUSTER TEST 1A
before proceeding with this test. For connector terminal identification, refer to CONNECTOR IDENTIFICATION
. For wiring diagrams, refer to WIRING DIAGRAMS
. Perform, after each repair, TEST VER-1A - VERIFICATION PROCEDURE
.
CAUTION:
Always turn ignition switch to OFF position prior to disconnecting or connecting any module connector.
- Remove instrument cluster. See INSTRUMENT PANEL - ANALOG article. Remove inoperative bulb. If bulb is burned out, replace bulb. If bulb is not burned out, go to next step.
- Inspect wiring diagram and evaluate which instrument cluster provides; power or ground for inoperative bulb. See WIRING DIAGRAMS . Using external ohmmeter or voltmeter, check appropriate power or ground circuit. If circuit is okay, replace instrument cluster. If power or ground is not available at appropriate circuit, repair open circuit.