Instrument Cluster Test 2A - All Gauges Do Not Operate
NOTE:
Perform INSTRUMENT CLUSTER TEST 1A
before proceeding with this test. For connector terminal identification, refer to CONNECTOR IDENTIFICATION
. For wiring diagrams, refer to WIRING DIAGRAMS
. Perform, after each repair, TEST VER-1A - VERIFICATION PROCEDURE
.
CAUTION:
Always turn ignition switch to OFF position prior to disconnecting or connecting any module connector.
- Remove and inspect fuse No. 11. Fuse No. 11 is located in junction block behind left kick panel. If fuse is okay, go to next step. If fuse is open, go to VEHICLE COMMUNICATIONS .
- Turn ignition off. Remove instrument cluster. See INSTRUMENT PANEL - ANALOG article. Turn ignition on. Using external voltmeter, measure voltage between ground and Black instrument cluster connector C1 terminal No. 2 (Dark Blue/White wire). If voltage is 10 volts or less, repair open Dark Blue/White wire. If voltage is more than 10 volts, replace instrument cluster.