Exhaust Gas RECIRCULATION: Operation
The system consists of:
- An EGR valve assembly. The valve is located on the rear of the engine above the exhaust manifold.
- An EGR solenoid. The EGR solenoid controls the "on time" of the EGR valve.
- The ECM operates the EGR solenoid. The ECM is located in the left front corner of the engine compartment, in front of the battery.
- An EGR tube connects a passage in the EGR valve to the intake manifold.
- The vacuum pump supplies vacuum for the EGR solenoid and the EGR valve. This pump also supplies vacuum for operation of the power brake booster and the heating and air conditioning system. The pump is located internally in the front of the engine block and is driven by the crankshaft gear.
- Vacuum lines and hoses connect the various components.
When the ECM supplies a variable ground signal to the EGR solenoid, EGR system operation starts to occur. The ECM will monitor and determine when to supply and remove this variable ground signal. This will depend on inputs from the engine coolant temperature, throttle position and engine speed sensors.
When the variable ground signal is supplied to the EGR solenoid, vacuum from the vacuum pump will be allowed to pass through the EGR solenoid and on to the EGR valve with a connecting hose.
Exhaust gas recirculation will begin in this order when:
- The ECM determines that EGR system operation is necessary.
- The engine is running to operate the vacuum pump.
- A variable ground signal is supplied to the EGR solenoid.
- Variable vacuum passes through the EGR solenoid to the EGR valve.
- The inlet seat (poppet valve) at the bottom of the EGR valve opens to recirculate exhaust gas back into the intake manifold.
The EGR system will be shut down by the ECM after 60 seconds of continuous engine idling to improve idle quality.