LEMON Manuals: Even more car manuals for everyone

Vacuum Control System: Notes

Use an adjustable vacuum test set (special tool C-3707-B) and a suitable vacuum pump to test the HVAC vacuum control system. With a finger placed over the end of the vacuum test hose probe, adjust the bleed valve on the test set gauge to obtain a vacuum of exactly 8 in. Hg. (27 kPa). See Fig 1 . Release and block the end of the probe several times to verify that the vacuum reading returns to the exact 8 in. Hg. (27 kPa) setting. Otherwise, a false reading will be obtained during testing.

Fig 1: Testing Vacuum Control System
G00180515Courtesy of CHRYSLER CORP.
Fig 2: HVAC Vacuum System Diagnosis Chart
G00180516Courtesy of CHRYSLER CORP.