Test 9A: Pump Motor Not Working Properly
NOTE:
After each repair, perform TEST VER-1A: VERIFICATION TEST
to confirm problem has been corrected.
NOTE:
Pump/motor is integral part of Hydraulic Control Unit (HCU).
- With ignition on, listen for pump/motor operation. If pump/motor runs continuously, replace Controller Anti-Lock Brakes (CAB). See CONTROLLER ANTI-LOCK BRAKE under REMOVAL & INSTALLATION. If pump/motor does not run continuously, go to next step.
- Turn ignition on. Using scan tool, read and then erase DTCs. Turn ignition off, then on. Using scan tool, actuate ABS PUMP MOTOR. If pump/motor does not run when actuated, go to next step. If pump/motor runs when actuated, go to step 12 .
- Turn ignition off. Remove and inspect ABS pump fuse "K" from Power Distribution Center (PDC). Fuses are identified inside PDC cover. If fuse is okay, leave fuse removed, and go to next step. If fuse is blown, leave fuse removed, and go to step 7 .
- Inspect fused B+ circuit (Red/Dark Green wire) between CAB connector and PDC for signs of intermittent short to ground. Repair Red/Dark Green wire as necessary, and replace fuse. If Red/Dark Green wire is okay, leave fuse removed and go to next step.
- Ensure ignition is off. Disconnect CAB connector. Using a test light connected to battery voltage, probe CAB connector terminal No. 25, fused B+ circuit (Red/Dark Green wire). If test light illuminates, repair Red/Dark Green wire for short to ground, and replace fuse. If test light does not illuminate, leave fuse removed, and go to next step.
- Reconnect CAB connector. Using a test light connected to battery voltage, probe PDC fused B+ terminal (Red/Dark Green wire). If test light illuminate, replace CAB and fuse. See CONTROLLER ANTI-LOCK BRAKE under REMOVAL & INSTALLATION. If test light does not illuminate, replace defective fuse.
- Turn ignition on. Using a test light connected to ground, probe PDC voltage supply terminal (Red/Black wire). If test light illuminates, leave fuse removed, and go to next step. If test light does not illuminate, repair open Red/Black wire, and replace fuse.
- Disconnect pump/motor connector. Connect a jumper wire between PDC voltage supply terminal (Red/Black wire) and pump/motor connector (component side) terminal No. 2, voltage circuit (Red wire). Connect a second jumper wire between ground and pump/motor connector (component side) terminal No. 1, ground circuit (Tan wire). If pump/motor operates, leave fuse removed, and go to next step. If pump/motor does not operate, replace pump/motor and HCU assembly, and fuse. See HYDRAULIC CONTROL UNIT under REMOVAL & INSTALLATION.
- Ensure ignition is off. Disconnect CAB connector. Inspect connector for pushed-out terminals, damaged terminals, or miswired terminals. Repair connector as necessary. Check resistance of fused B+ circuit (Red/Dark Green wire) between CAB connector terminal No. 25 and PDC. If resistance is less than 10 ohms, leave fuse removed, and go to next step. If resistance is 10 ohms or more, repair open in Red/Dark Green wire, and replace fuse.
- Check resistance between ground and CAB connector terminals No. 8 and 24, ground circuits (Black wires). If resistance is less than one ohm on both circuits, reconnect CAB connector, replace fuse, and go to next step. If resistance is one ohm or more on either circuit, repair open in Black wire(s), and replace fuse.
- Turn ignition on. Using scan tool, actuate ABS PUMP MOTOR. Check voltage drop across pump/motor ground circuit (Tan wire). If voltage is less than .1 volt, replace CAB and fuse. See CONTROLLER ANTI-LOCK BRAKE under REMOVAL & INSTALLATION. If voltage is .1 volt or more, repair open Tan wire, and replace fuse.
- Turn ignition off. Inspect related wiring harness, connectors and terminals for defective connectors, bare or broken wires. See WIRING DIAGRAMS . Repair any problems found as necessary. If no problems are found, check if any Technical Service Bulletins (TSB) apply to vehicle.