Test 2D - Bus Short To Battery
NOTE:
For connector terminal identification see CONNECTOR IDENTIFICATION
. For wiring diagrams, see WIRING DIAGRAMS
. Perform, after each repair, TEST VER-1A - VERIFICATION PROCEDURE
.
CAUTION:
Always turn ignition off prior to disconnecting any module connector.
- Turn ignition off. Using external voltmeter, measure voltage between ground and BCM 14-pin connector terminals No. 3 (Violet/Brown wire), No. 5 (Violet/Brown wire) and No. 6 (Violet/Dark Green wire). If voltage of any terminal is more than .5 volt, repair short to voltage in appropriate circuit. See WIRING DIAGRAMS . If voltage of all terminals are .5 volt or less, go to next step.
- Measure voltage between ground and BCM 14-pin connector terminals No. 9 (White/Black wire), No. 13 (White/Black wire) and No. 14 (White/Dark Green wire). If voltage of any terminal is more than .5 volt, repair short to voltage in appropriate circuit. See WIRING DIAGRAMS . If voltage of all terminals are .5 volt or less, replace BCM.