Test FC-10A - O2S Stays Below Center (Lean) (DTC 51)
NOTE:
For connector terminal identification, see CONNECTOR IDENTIFICATION
. For appropriate wiring diagram, see WIRING DIAGRAMS
at end of article.
- Set parking brake and start engine. Using DRB-II, set engine speed to 1500 RPM. Read O2 sensor voltage value. If O2 sensor voltage is always less than 0.5 volt, go to next step. If O2 sensor voltage is always more than 0.5 volt, go to step 4).
- If O2 sensor voltage is always at zero volt, repair O2 sensor connector signal circuit (Black/Dark Green wire) for short to ground. Perform VERIFICATION PROCEDURE VER-2. If O2 sensor voltage is not always at zero volt, go to next step.
- Check for tracking from O2 sensor signal circuit (Black/Dark Green wire) to ground. Check connectors for dirt and grease build-up. Repair as required. Perform VERIFICATION PROCEDURE VER-2. If connectors are okay, a condition causing engine to run lean is indicated. Go to TEST NF-1A.
- At this time, condition required to set fault is not present. O2S STAYS BELOW CENTER (LEAN) fault sets if O2 sensor output voltage stays less than 0.5 volt without changing for more than 8 minutes. Possible causes are: major vacuum leak, low fuel pressure, other engine sensor calibrations, ignition system failure, O2 sensor failure, or fuel contamination. Go to TEST NF-1A.