Bench Test: Stator
NOTE:
The 114-amp alternator can be tested for grounded stator only. Stator windings are Delta Wound and cannot be tested with common automotive service test equipment.
- Remove varnish from a spot on stator frame. Use an ohmmeter to check for continuity between spot on stator frame and each stator lead terminal. If continuity exists, stator lead is grounded and should be replaced.
- If stator is not grounded and all other components have tested satisfactory, it can be suspected that stator is open or shorted and should be replaced.