Charging Circuit Resistance
- Check battery for full charge, recharge or replace before performing test. Disconnect negative battery cable from battery. Disconnect "BAT" lead at alternator output terminal. See Fig 1.
- Connect D.C. ammeter set to 0-100 amp scale, in series between alternator "BAT" terminal and disconnected "BAT" lead wire. Connect ammeter positive lead to "BAT" terminal and negative lead to "BAT" lead.
- Connect positive lead of voltmeter (range 0-18 volts minimum) to "BAT" lead wire. Connect negative voltmeter lead to positive battery post.
- Connect tachometer to engine and reconnect negative battery cable.NOTE: Be sure carbon pile rheostat is in "Open" or "Off" position before connecting leads.
- Connect variable carbon pile rheostat across negative and positive terminals of battery.
- Start engine and maintain engine speed at idle. Adjust engine speed and carbon pile rheostat to obtain 20 amps flowing in circuit. Observe voltmeter reading. Reading should not exceed .5 volts.
- If voltmeter reading was more than .5 volts, inspect, clean and tighten all connections in charging circuit. A voltage drop test may be performed at each connection to locate connection with excessive resistance.
- If voltmeter reading was okay, turn engine off and disconnect all test equipment.