Rotor Field Coil
- To check for open field coil, connect ohmmeter to slip rings. Ohmmeter reading should be between 1.5 and 2.0 ohms on rotor coils at ambient temperature. See Fig 1.Fig 1: Ohmmeter Hookup for Testing Rotor Field Coils Worn or rough slip rings require rotor replacement.NOTE: Resistance between 2.5 and 3.0 ohms would result from alternator rotors that have been operated on vehicle at higher engine compartment temperatures. Readings above 3.5 ohms would indicate high resistance rotor coils and further testing or replacement may be required.
- To check for shorted field coil, connect ohmmeter to both slip rings. If reading is below 1.5 ohms, field coil is shorted. To check rotor for grounded field coil, connect ohmmeter from each slip ring to rotor shaft. See Fig 2.
- The ohmmeter should read infinite. If reading is zero or higher, rotor is grounded. Replace rotor assembly.