Circuit/System Testing
- Ignition/Vehicle & All vehicle systems - Off
- Disconnect the electrical connector:X92 USB Receptacle
- Test for less than 10 ohms between the test points:Ground circuit terminal 4 & Ground
- If 10 ohms or greater
- Disconnect the ground connection:Ground terminal
- Test for less than 2 ohms between the test points:Ground circuit terminal 4 @Component harness & The other end of the circuit@Ground terminal
- If 2 ohms or greater - Repair the open/high resistance in the circuit.
- If less than 2 ohms - Repair the open/high resistance in the ground connection.
- Go to next step: If less than 10 ohms
- Ignition - On / Vehicle - In Service Mode
- Verify a test lamp turns On between the test points:Ignition circuit terminal 6 & Ground
- If the test lamp does not turn On and the circuit fuse is OK
- Ignition/Vehicle - Off & Remove - Test lamp
- Test for less than 2 ohms between the test points:Ignition circuit terminal 6 @Component harness & Output terminal@Fuse
- If 2 ohms or greater - Repair the open/high resistance in the circuit.
- If less than 2 ohms - Refer to: Retained Accessory Power Malfunction (WIth ATH/BTM)Retained Accessory Power Malfunction (Without ATH/BTM)
- If the test lamp does not turn On and the circuit fuse is open
- Ignition/Vehicle - Off & Remove - Test lamp
- Test for infinite resistance between the test points:Ignition circuit terminal 6 & Ground
- If less than infinite resistance - Repair the short to ground on the circuit.
- If infinite resistance - Test or replace the component:X92 USB Receptacle
- Go to next step: If the test lamp turns On
- Test or replace the component:X92 USB Receptacle
NOTE:
It may take up to 2 min for all vehicle systems to power down before an accurate ground or low reference circuit continuity test can be performed.