LEMON Manuals: Even more car manuals for everyone

Circuit/System Testing

  1. Ignition/Vehicle & All vehicle systems» Off
    NOTE: It may take up to 2 min for all vehicle systems to power down before an accurate ground or low reference circuit continuity test can be performed.
  2. Remove the component: KR5 Rear Defogger Relay
  3. Test for less than 10 Ω between the test points: Ground circuit terminal 2 & Ground
    • If 10 Ω or greater 
    1. Ground Connection» Disconnect
    2. Test for less than 2 Ω between the test points: Ground circuit terminal 2 & Ground Connection
      • If 2 Ω or greater» Repair the open/high resistance in the circuit.
      • If less than 2 Ω» Repair the open/high resistance in the ground connection.
    • If less than 10 Ω 
  4. Connect a test lamp between the test points: Control circuit terminal 1 & Ground circuit terminal 2
  5. Ignition» On / Vehicle» In Service Mode
  6. Perform the scan tool control function: Rear Defogger» On and Off

    Verify the test lamp turns On and Off.

    • If the test lamp is always Off 
    1. Ignition/Vehicle» Off & Remove» Test lamp
    2. Disconnect the electrical connector: K33 HVAC Control Module
    3. Test for infinite resistance between the test points: Control circuit terminal 1 @ Relay Socket & Ground
      • If less than infinite resistance» Repair the short to ground on the circuit.
      • If infinite resistance
    4. Test for less than 2 Ω between the test points: Control circuit terminal 1 @ Relay Socket & Terminal 19 X2 @ Control module harness
      • If 2 Ω or greater» Repair the open/high resistance in the circuit.
      • If less than 2 Ω» Replace the component: K33 HVAC Control Module
    • If the test lamp is always On 
    1. Ignition/Vehicle» Off & Remove» Test lamp
    2. Disconnect the electrical connector: K33 HVAC Control Module
    3. Ignition» On / Vehicle» In Service Mode
    4. Test for less than 1 V between the test points: Control circuit terminal 1 @ Relay Socket & Ground
      • If 1 V or greater» Repair the short to voltage on the circuit.
      • If less than 1 V» Replace the component: K33 HVAC Control Module
    • If the test lamp turns On and Off 
  7. Test or replace the component: KR5 Rear Defogger Relay