Circuit/System Testing
Lumbar Switch Circuit Test
- Ignition OFF, disconnect the harness connector at the lumbar adjuster switch.
- Ignition ON, verify that a test lamp illuminates between the B+ circuit terminal G and ground.
- If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the MSM.
- Verify that all scan tool lumbar switch parameters are Inactive.
- If not the specified value, test the appropriate signal circuits listed below for a short to voltage. If the circuit tests normal, replace the MSM.
- Lumbar horizontal forward terminal A
- Lumbar horizontal rearward terminal F
- Lumbar vertical upward terminal C
- Lumbar vertical downward terminal B
- Install a 3A fused jumper wire between the appropriate signal circuit listed below and the B+ circuit terminal G. Verify the scan tool Lumbar Switch parameter is Active.
- Lumbar horizontal forward terminal A
- Lumbar horizontal rearward terminal F
- Lumbar vertical upward terminal C
- Lumbar vertical downward terminal B
- If not the specified value, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the MSM.
- If all circuits test normal, test or replace the lumbar switch.
Lumbar Motor Control Circuit Test
- Ignition OFF, disconnect the X3 harness connector at the MSM.
- Ignition ON, verify that a test lamp illuminates between the B+ circuit terminal 2 and ground.
- If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
- Ignition OFF, connect the X3 harness connector at the MSM and disconnect the harness connector at the appropriate lumbar motor.
- Connect a test lamp between control circuit terminal 1 and control circuit terminal 5.
- Ignition ON, command the appropriate lumbar motor in the Up/Down or Forward/Rearward directions with a scan tool. The test lamp should turn ON when commanding the up and down or forward and rearward states.
- If the test lamp remains OFF during either of the commands, test the control circuits for an open/high resistance. If the circuits test normal replace the MSM.
- If all circuits test normal, test or replace the lumbar motor.