LEMON Manuals: Even more car manuals for everyone

Circuit/System Testing

ECM Park Switch Circuit Malfunction

  1. Ignition OFF, disconnect the X175 AT inline 20-Way connector at the transmission.
  2. Ignition OFF and scan tool disconnected, open and close the driver door, and wait 1 minute. Test for less than 5 Ω between the ground circuit terminal K and ground.
    • If greater than the specified range, test the ground circuit for an open/high resistance.
  3. Ignition ON, verify the scan tool ECM PNP Switch parameter is In Gear.
    • If not the specified value, test the signal circuit terminal W for a short to ground. If the circuit tests normal, replace the ECM.
  4. Ignition ON, install a 3A fused jumper wire between the signal circuit terminal W and the ground circuit terminal K. Verify the scan tool ECM PNP switch parameter is Park/Neutral.
    • If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM.
  5. If all circuits test normal, test or replace the internal mode switch (IMS).

Starter Relay Circuit Malfunction

  1. Ignition OFF, disconnect the CRNK relay.
  2. Ignition ON, verify that a test lamp does not illuminate between the control circuit terminal 86 and ground.
    • If the test lamp illuminates, test the control circuit for a short to voltage.
  3. Ignition ON, verify a test lamp illuminates between the ignition circuit terminal 85 and ground.
    • If the test lamp does not illuminate, test the ignition circuit for a short to ground or an open/high resistance.
  4. Verify a test lamp illuminates between the B+ circuit terminal 30 and ground.
    • If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
  5. Apply the parking brake and shift the transmission into park. Connect a 40A fused jumper wire between the B+ circuit terminal 30 and the control circuit terminal 87. Verify the starter solenoid engages and the engine cranks.
    • If the solenoid does not engage, test the control output circuit for an open/high resistance. If the circuit tests normal, test or replace the starter motor.
  6. Connect a test lamp between the ignition circuit terminal 85 and the control circuit terminal 86.
  7. Transmission in park, turn the ignition switch between the OFF and CRANK positions. The test lamp should turn ON and OFF when changing between the positions.
    • If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the ECM.
    • If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM.
  8. If all circuits test normal, test or replace the CRNK relay.