Circuit/System Testing
ECM Park Switch Circuit Malfunction
- Ignition OFF, disconnect the X175 AT inline 20-Way connector at the transmission.
- Ignition OFF and scan tool disconnected, open and close the driver door, and wait 1 minute. Test for less than 5 Ω between the ground circuit terminal K and ground.
- If greater than the specified range, test the ground circuit for an open/high resistance.
- Ignition ON, verify the scan tool ECM PNP Switch parameter is In Gear.
- If not the specified value, test the signal circuit terminal W for a short to ground. If the circuit tests normal, replace the ECM.
- Ignition ON, install a 3A fused jumper wire between the signal circuit terminal W and the ground circuit terminal K. Verify the scan tool ECM PNP switch parameter is Park/Neutral.
- If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM.
- If all circuits test normal, test or replace the internal mode switch (IMS).
Starter Relay Circuit Malfunction
- Ignition OFF, disconnect the CRNK relay.
- Ignition ON, verify that a test lamp does not illuminate between the control circuit terminal 86 and ground.
- If the test lamp illuminates, test the control circuit for a short to voltage.
- Ignition ON, verify a test lamp illuminates between the ignition circuit terminal 85 and ground.
- If the test lamp does not illuminate, test the ignition circuit for a short to ground or an open/high resistance.
- Verify a test lamp illuminates between the B+ circuit terminal 30 and ground.
- If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.
- Apply the parking brake and shift the transmission into park. Connect a 40A fused jumper wire between the B+ circuit terminal 30 and the control circuit terminal 87. Verify the starter solenoid engages and the engine cranks.
- If the solenoid does not engage, test the control output circuit for an open/high resistance. If the circuit tests normal, test or replace the starter motor.
- Connect a test lamp between the ignition circuit terminal 85 and the control circuit terminal 86.
- Transmission in park, turn the ignition switch between the OFF and CRANK positions. The test lamp should turn ON and OFF when changing between the positions.
- If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the ECM.
- If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM.
- If all circuits test normal, test or replace the CRNK relay.