LEMON Manuals: Even more car manuals for everyone

Charge Mode: Notes

The BCM will enter Charge Mode whenever one of the following conditions is met:

Once one of these conditions is met, the generator battery control module will set the targeted generator output voltage to 13.4 volts and then ramp that voltage up to 14.5 volts at a rate of 50 mV per second.