Circuit Description
A linear Exhaust Gas Recirculation (EGR) valve is used on this system. Powertrain Control Module (PCM) commands EGR valve to operate when necessary by controlling a ground signal through PCM. This can be monitored on a scan tool by selecting DESIRED EGR POSITION function. Ignition voltage is supplied to EGR valve thorough a fuse. PCM monitors results of its command through a feedback signal. Feedback signal is the actual position of the EGR pintle. This feedback signal can also be monitored on a scan tool by selecting ACTUAL EGR POSITION function. The ACTUAL EGR POSITION should always be near the commanded or DESIRED EGR POSITION.
Conditions for setting this DTC are as follows:
- DTC(s) P0106, P0107, P0112, P0113, P0117, P0118, P0121, P0122, P0123, P0200, P0300-P0304, P0335, P0502, P0506, P0507 and P1441 not set.
- Engine speed is 900-1700 RPM (A/T).
- Engine speed is 1000-2200 RPM (M/T).
- ECT greater than 167°F (75°C).
- BARO greater than 72 kPa.
- MAP is 12-32 kPa.
- TP angle less than one percent.
- Vehicle speed is greater than 20 MPH.
- EGR flow restricted.