Brushes & Springs

  1. Connect ohmmeter lead to positive brush holder and other lead to negative brush holder. If test needle moves, brush holder assembly is shorted and must be replaced.
  2. Check brush length. If less than specification, replace brushes. See the MINIMUM BRUSH LENGTH SPECIFICATIONS . Check spring tension. Spring tension should be 37-48 ozs. (1050-1350 g). Brushes must move freely in holders.