Wiper Motor Housing: Installation
Reverse removal procedures using parts supplied in service package. After wiper motor is fully assembled, place thrust pin in casting with insert about 1/32" above rear of pin.
NOTE:
Use "Wiper Motor Housing" removal and installation procedures for replacing the following components: Wiper gear assembly, intermediate gear assembly, wiper magnet assembly, park switch actuator, brush holder assembly and motor armature.
WIPER MOTOR SPECIFICATIONS
| Application | Specification | |
|---|---|---|
| Operating Voltage | 12 Volts | |
| Current Draw (No Load) | ||
| Low Speed | 3.5 Amps Max. | |
| High Speed | 5.0 Amps Max. | |
| Crank Arm Rotation | Counterclockwise | |