Circuit/System Testing
- Inspect the turbocharger and the wastegate solenoid valve for damage. Refer to Turbocharger Cleaning and Inspection
- Ignition OFF, disconnect the harness connector at the Q42 turbocharger wastegate solenoid valve.
- Ignition ON, verify that a test lamp illuminates between the ignition circuit terminal 1 and ground.
- If the test lamp does not illuminate, test the ignition circuit for a short to ground or an open/high resistance. If the circuit tests normal and the ignition circuit fuse is open, test all components connected to the ignition circuit and replace as necessary.
- Connect a test lamp between the control circuit terminal 2 and the ignition circuit terminal 1.
- Command the Turbocharger Wastegate Solenoid Valve to 50% with a scan tool. The test lamp should illuminate when commanded to 50% and turn OFF when commanded to 0%.
- If the test lamp is always ON, test the control circuit terminal 2 for a short to ground. If the circuit tests normal, replace the K20 ECM.
- If the test lamp is always OFF, test the control circuit terminal 2 for a short to voltage or an open/high resistance. If the circuit tests normal, replace the K20 ECM.
- Test for 2.6-4.6 V between the control circuit terminal 2 and ground.
- If the voltage is not within the specified range, replace the K20 ECM.
- If all circuits test normal, test or replace the Q42 turbocharger wastegate solenoid valve.