Installation Procedure
- Place the retainer and a NEW front exhaust manifold pipe seal over the left exhaust manifold.
- Position a NEW exhaust manifold gasket between the left exhaust manifold and the left cylinder head.
- Insert the left exhaust manifold into the front exhaust manifold pipe and up to the left cylinder head.
- Install the left exhaust manifold bolts.
Tighten: Tighten the exhaust manifold bolts to 25 N.m (18 lb. ft.).
- Install the 2 bolts attaching the left exhaust manifold to the front exhaust manifold pipe.
Tighten: Tighten the front exhaust manifold pipe bolts to 25 N.m (18 lb. ft.).
- Install the oxygen sensor. Refer to Heated Oxygen Sensor (HO2S) Replacement Bank 2 Sensor 1 in Engine Controls-4.6L.
- Install the front engine mount bracket. Refer to Engine Mount Bracket Replacement - Front in Engine Mechanical-4.6L.
- Lower the vehicle.
- Install the new gasket to the secondary AIR tube.
- Install the 2 nuts (2) attaching the secondary AIR tube (3) to the exhaust manifold (1).
Tighten: Tighten the secondary AIR tube nuts to 12 N.m (106 lb. in.).
NOTE:
Refer to Fastener Notice in Cautions and Notices.