Note On Intermittents
PCM data displays P.2.2 and P.2.3 indicating status of each of 4 circuits. A pull-up resistor produces a battery voltage signal at PCM terminal when circuit is open and no signal when circuit is to ground. See table in Code E91 electrical schematic.
PCM CODE E91 DATA
| Selector Position | CKT 773 1 P.2.2 | CKT 772 1 P.2.2 | CKT 771 2 P.2.3 | CKT 776 2 P.2.3 |
|---|---|---|---|---|
| P | 1 | 1 | 0 | 0 |
| R | 1 | 0 | 0 | 1 |
| N | 1 | 0 | 1 | 0 |
| OD | 0 | 0 | 1 | 1 |
| 3 | 0 | 0 | 0 | 0 |
| 2 | 0 | 1 | 0 | 1 |
| 1 | 0 | 1 | 1 | 0 |
PCM VOLTAGE CHECK
| PCM TERM | SW CLOSED | SW OPEN |
|---|---|---|
| F8 | 0 to 0.3 Volts | BATTERY |
| C10 | 0 to 0.3 Volts | BATTERY |
| F7 | 0 to 0.3 Volts | BATTERY |
| A2 | 0 to 0.3 Volts | BATTERY |