LEMON Manuals: Even more car manuals for everyone

Code E23: Est Circuit Problem (2 Of 2)

The distributor reference ground circuit No. 453 is a common ground between ECM and HEI. The ECM and HEI compare by-pass, EST and reference voltages to ground voltage on circuit No. 453. Circuit No. 453 open to HEI or ECM can cause a failure of ECM to recognize a reference pulse or failure of module to recognize an EST pulse.

The ECM compares status of EST circuit to status of by-pass circuit in order to detect a fault and set Code E23. If ECM has by-pass at 5 volts, module should accept EST information. EST voltage should be high (.5-2.8 volts). If by-pass is zero volts, module should ground EST circuit and EST voltage should be low (less than .5 volt).

Possible causes of Code E23 are:

NOTE: Test numbers refer to test numbers on diagnostic chart.

Test Number 5)  Checks for HEI module ability to recognize a voltage on by-pass circuit and to stop grounding EST (ECM controlling timing).

Test Number 6)  Checks for by-pass signal to module. If by-pass is being sent by ECM to HEI, and if module is interpreting by-pass voltage correctly, the module will switch off the ground to EST.

Test Number 7)  If chart leads to EST circuit and circuit is okay, a fault may exist in 6-way weatherpack. Check for proper connector mating and for pins backing out of weatherpack. If connector is okay, reconnect 6-way, clear codes and retest.

Fig 1: Code E23: Circuit Diagram (2 of 2)
G90F17256
Fig 2: Code E23: Flow Chart (2 of 2)
G90C14755