One Or More Windows Inoperative From Individual Switches, Operate From Master Switch
- Disconnect inoperative window switch connector. Turn ignition switch to RUN position. On 4 door models, press LOCKOUT switch to OFF position. Connect test light between ground and inoperative connector terminal "B" (Dark Blue wire). See Figure .
- If test light illuminates, replace inoperative window switch. Recheck system operation. If test light does not illuminate, check for open in Dark Blue wire (4 door) between inoperative switch and master window switch or Brown wire between fuse block and master window switch (2-door).