One Mirror Does Not Operate In Up/Down Positions (Left/Right Positions Operate Normally)
- Disconnect inoperative power mirror. On left mirror, connect test light between power mirror connector terminal "D" (Yellow wire) and ground. On right mirror, connect test light between power mirror connector terminal "D" (Brown/White wire) and ground. With inoperative mirror selected, move mirror select switch to up position. If test light glows, go to next step. If test light does not glow, check for poor connection or open in Yellow or Brown/White wire between power mirror switch and inoperative power mirror. If connection and circuit are okay, replace power mirror switch.
- On left mirror, connect test light between power mirror connector terminals "D" (Yellow wire) and "C" (Light Blue wire). On right mirror, connect test light between power mirror connector terminals "D" (Brown/White wire) and "C" (Gray wire). Move mirror select switch to up position. If test light glows, check for poor connections at power mirror. If connections are okay, replace power mirror motor pack. If test light does not glow, repair poor connection or open in Light Blue or Gray wire between power mirror switch and inoperative power mirror.