TECHNICAL SERVICE BULLETIN

Reference Number(s): 92-1-1, Date of Issue:  05/30/91

INADEQUATE HEAT/AIR FLOW - DISTRIBUTION-REVISED AIR DUCT

Model(s): 1991 Buick Roadmaster Estate Wagons

1992 Buick Roadmaster Sedans

Bulletin No.: Buick 92-1-1

Date: 05/30/1991

BULLETIN ILLUSTRATION LIST

Fig 1: Graphic
GE00W008093

CONDITION

Some 1991-92 Roadmasters may experience inadequate driver's side heat.

CAUSE

Inadequate heat and air flow distribution to the driver's side from the heater floor outlet.

CORRECTION

Install revised heater floor outlet.

PROCEDURE, PARTS AND INFORMATION

Install a revised heater floor outlet, P/N 10100996. The revised outlet may be identified from the old outlet by the addition of a rectangular opening and the removal of an extension tab on the left hand side of the outlet, as shown in Fig 1 .

Parts are currently available from GMSPO.

Vehicles prior to the following breakpoints are affected:

VIN BREAKPOINTS

Plant VIN
Willow Run MW400704
Arlington NR400212

WARRANTY INFORMATION

Labor Operation Number: D1517

Labor Time: .2 Hour