Circuit Operation
A permanent magnet (PM) motor operates each of the power windows. Each motor raises or lowers the glass when voltage is supplied to it. The direction the motor turns depends on the polarity of the supply voltage. The switches control the supply voltages polarity.
The master switch assembly controls all of the motors. Each power window switch controls only one of the motors.
Each motor is protected by a built in electronic circuit breaker PTC. If a power window switch is held too long with the window obstructed or after the window is fully up or down, the PTC resistance increases. The resistance returns to normal after voltage is removed from the motor.