2003 3BMXV03.0UL2
- General Description - Fuel system monitoring looks for permanent deviations of A/F controller (lean and rich) from mean position.
- Monitoring Structure - If fuel system is suddenly and significantly disturbed (leaky injection valve) and A/F controller reaches its restriction or a permanent deviation from mean position reaches additional lean or rich thresholds and accumulated time (sum of all excesses for rich and lean) is greater than a fixed limit during a defined period, a fault for long term trim will be detected and stored. See Figure.