Leak Detection Pump, FSI, Checking
Special tools and workshop equipment required
- Hand-held multimeter -V.A.G 1526C-
- Voltage tester -V.A.G 1527B-
- Connector test set -V.A.G 1594C-
- Adapter cable -V.A.G 1598/39-
- Test box -V.A.G 1598/42-
- Vehicle diagnostic, testing, and information system -VAS 5051B- with Diagnostic Cable -VAS 5051/5A
Procedure
- Ignition switched on.
- -VAS 5051B- connected with -VAS 5051/5A-, Vehicle Self-Diagnosis selected.
Check activation
Display on -VAS 5051B- :
- Tap "On Board Diagnostic" in selection -1- and activate by tapping the → button.
Display on -VAS 5051B- :
- Tap "01 - Engine Electronics" vehicle system in selection -1- and activate by tapping the → button.
Display on -VAS 5051B-:
- Tap "005 - Output Diagnostic Test Mode (DTM)" function in selection -1- and activate by pressing the → button.
Display on -VAS 5051B- :
- Output diagnostic test mode waiting, Advancing by switching required.
- Component designation of current activated actuator.
- Press the → button repeatedly, until Leak Detection Pump (LDP) -V144- is activated.
NOTE:
The sound of the leak detection pump running can be heard at the left rear wheel housing.
- End function "005 - output Diagnostic Test Mode (DTM)" by pressing ← button.
- Select "022 - End output" function in selection.
- Switch off ignition.
If Leak Detection Pump (LDP) for fuel system is not activated (no operating noise audible):
- Remove leak detection pump (LDP) and disconnect the electrical connection. Refer to Leak Detection Pump .
Checking internal resistance
- Connect -V.A.G 1526C- for resistance measurement as follows.
| Leak Detection Pump (LDP) Terminal | Specified value |
|---|---|
| -1- + -3- | 640 720 Ω |
| -2- + -3- | 15 17 Ω |
If the specifications are not obtained:
- Replace the leak detection pump (LDP). Refer to Leak Detection Pump .
If the specified values are achieved:
- Check voltage supply of leak detection pump.
Checking voltage supply
NOTE:
Voltage for leak detection pump is supplied via Motronic Engine Control Module (ECM) Power Supply Relay -J271-.
- Fuse for leak detection pump OK
- Connect -V.A.G 1527B- as follows:
| Harness Connector Terminal | Measure to |
|---|---|
| -3- | Engine Ground (GND) |
- Briefly operate starter.
- LED must light up.
If LED does not light up:
- Check electrical harness connection from terminal -3- via fuse to Motronic engine control module (ECM) power supply relay for open circuit according to wiring diagram.
- Repair open circuit in wiring according to wiring diagram.
Checking output wiring
- Connect -V.A.G 1527B- as follows:
| Harness Connector Terminal | Measure to |
|---|---|
| -2- | Battery positive (B+) |
- Initiate output Diagnostic Test Mode (DTM). Refer to Leak Detection Pump, 8-Cylinder MPI, Checking .
Display on -VAS 5051B- :
- Output diagnostic test mode waiting, Advancing by switching required.
- Evaporative emission (EVAP) canister purge regulator valve 1.
- Press the → button repeatedly, until leak detection pump (LDP) is activated.
- LED must blink.
If LED does not blink:
- End function "005 - output Diagnostic Test Mode (DTM)" by pressing ← button.
- Select "022 - End output" function in selection.
- Switch off ignition.
- Connect -V.A.G 1598/42- to wiring harness with -V.A.G 1598/39-1- or -V.A.G 1598/39-2-. Clamp test box ground (GND) clip to battery negative terminal. The procedure will indicate whether the engine control module is to be connected to the test box or not.
CAUTION:
Risk of destroying electrical components.
- Before connecting the test leads, switch on the respective measuring range and observe the test conditions.
- Check the following wire connection for open circuit and short circuit to Ground (GND) and B+:
Engine Harness Connector Terminal -V.A.G 1598/42- Bushing 6-cylinder 3.2L FSI -2- B 24 8-cylinder 4.2L FSI -2- B 10 10-cylinder 5.2L FSI -2- A 55 - Repair wiring open circuit or short circuit according to wiring diagram.
If no malfunction is found, but leak diagnosis pump is not functional during output diagnostic test mode:
- Replace the leak detection pump (LDP). Refer to Leak Detection Pump .
- Observe procedures for after re-connecting engine control module (ECM). Refer to the appropriate Fuel Injection and Ignition General Information.
Checking input wiring
- Switch off ignition.
- Connect -V.A.G 1598/42- to wiring harness with -V.A.G 1598/39-1- or -V.A.G 1598/39-2-. Clamp test box ground (GND) clip to battery negative terminal. The procedure will indicate whether the engine control module is to be connected to the test box or not.
CAUTION:
Risk of destroying electrical components.
- Before connecting the test leads, switch on the respective measuring range and observe the test conditions.
- Check the following wire connection for open circuit and short circuit to ground (GND) and B+:
Engine Harness Connector Terminal -V.A.G 1598/42- Bushing 6-cylinder 3.2L FSI -1- B 20 8-cylinder 4.2L FSI -1- B 40 10-cylinder 5.2L FSI -1- B 40 - Repair wiring open circuit or short circuit according to wiring diagram.
- Observe procedures for after re-connecting engine control module (ECM). Refer to the appropriate Fuel Injection and Ignition General Information.