LEMON Manuals: Even more car manuals for everyone

Leak Detection Pump, FSI, Checking

Special tools and workshop equipment required 

Procedure 

Fig 1: Data Link Connector (DLC)
GW00016002Courtesy of AUDI OF AMERICA, LLC

Check activation 

Display on -VAS 5051B- :

Fig 2: Display On VAS 5051 - "On Board Diagnostic (OBD)"
GW00017829Courtesy of AUDI OF AMERICA, LLC

Display on -VAS 5051B- :

Fig 3: Display On VAS 5051 - "01 - Engine Electronics"
GW00017830Courtesy of AUDI OF AMERICA, LLC

Display on -VAS 5051B-:

Fig 4: Display On VAS 5051
GW00017831Courtesy of AUDI OF AMERICA, LLC

Display on -VAS 5051B- :

  1. Output diagnostic test mode waiting, Advancing by switching required.
  1. Component designation of current activated actuator.
Fig 5: Display On VAS 5051
GW00022414Courtesy of AUDI OF AMERICA, LLC
NOTE: The sound of the leak detection pump running can be heard at the left rear wheel housing.

If Leak Detection Pump (LDP) for fuel system is not activated (no operating noise audible):

Checking internal resistance 

Leak Detection Pump (LDP) Terminal Specified value
-1- + -3- 640 720 Ω
-2- + -3- 15 17 Ω
Fig 6: Locating 3-Pin Connector At Fuel System Leak Detection Pump V144
GW00000672Courtesy of AUDI OF AMERICA, LLC

If the specifications are not obtained:

If the specified values are achieved:

Checking voltage supply 

NOTE: Voltage for leak detection pump is supplied via Motronic Engine Control Module (ECM) Power Supply Relay -J271-.
Harness Connector Terminal Measure to
-3- Engine Ground (GND)
Fig 7: Identifying 3-Pin Connector
GW00000673Courtesy of AUDI OF AMERICA, LLC

If LED does not light up:

Fig 8: Identifying 3-Pin Connector
GW00000673Courtesy of AUDI OF AMERICA, LLC

Checking output wiring 

Harness Connector Terminal Measure to
-2- Battery positive (B+)
Fig 9: Identifying 3-Pin Connector
GW00000673Courtesy of AUDI OF AMERICA, LLC

Display on -VAS 5051B- :

  1. Output diagnostic test mode waiting, Advancing by switching required.
  1. Evaporative emission (EVAP) canister purge regulator valve 1.
Fig 10: Display On VAS 5051
GW00022414Courtesy of AUDI OF AMERICA, LLC

If LED does not blink:

Fig 11: Adapter Cable V.A.G 1598/39 & Test Box V.A.G 1598/42
GWWA24-0622Courtesy of AUDI OF AMERICA, LLC
CAUTION: Risk of destroying electrical components.
  • Before connecting the test leads, switch on the respective measuring range and observe the test conditions.

If no malfunction is found, but leak diagnosis pump is not functional during output diagnostic test mode:

Checking input wiring 

Fig 13: Adapter Cable V.A.G 1598/39 & Test Box V.A.G 1598/42
GW00018585Courtesy of AUDI OF AMERICA, LLC
CAUTION: Risk of destroying electrical components.
  • Before connecting the test leads, switch on the respective measuring range and observe the test conditions.