Heated O2 Sensor & O2 Sensor Heater Checking (GROUP 24, NO. 96-01)
Publication date: 1996-04-01Reference number: GROUP 24, NO. 96-01
HEATED O2 SENSOR & O2 SENSOR HEATER CHECKING
TECHNICAL SERVICE BULLETIN
HEATED OXYGEN SENSOR AND OXYGEN SENSOR HEATER AFTER THREE WAY CATALYTIC CONVERTOR, CHECKING
Model(s): 1996-on Audi A6 With OBD II MMS 411 Fuel System
Group: 24 - Multiport Fuel injection
Bulletin No.: 96-01
Date: April 1, 1996
SERVICE INFORMATION
The following repair information has been revised and will be integrated with the next Repair Manual update.
This information replaces pages 24-55 through 24-58 in the current version Repair Manual.
HEATED OXYGEN SENSOR (HO2S) AND OXYGEN SENSOR (02S) HEATER AFTER THREE WAY CATALYTIC CONVERTER (TWC), CHECKING
- G130 = 02S behind three way catalytic converter, bank 1.
- G131 = 02S 2 behind three way catalytic converter, bank 2.
- Disconnect connector for 02S behind three way catalytic converter -G130- or -G131-.
- Switch multimeter (Fluke 83 or equivalent) to measure resistance (ohm) and check for continuity between terminal 3 (GND wire) and 4 (signal wire) of heated oxygen sensor. See Fig 1 .
If there is continuity:
- Replace heated oxygen sensor.
If there is not continuity:
- Switch multimeter (Fluke 83 or equivalent) to 2 volt range and connect between terminals 3 (GND) and 4 (signal wire) on harness connector. See Fig 2 .
- Switch ignition ON.
Specified value: 400 +/- 50 mV
If the specified value is not obtained, check wiring to ECM as follows:
- Switch ignition OFF.
- Connect VAG 1598/19 test box to ECM wiring harness.
- Check following wiring connections for continuity. Refer to Fig 3 .
Specified value: Max. 1 ohm (ohm)
| Heated Oxygen Sensor | Connector Terminal | VAG 1598/19 Test Box Socket Number |
|---|---|---|
| -G130- | 3 | C17 |
| 4 | C20 | |
| -G131- | 3 | C17 |
| 4 | C21 |
If the specified value is not obtained:
- Eliminate open or short circuit.
If wiring OK:
- Replace ECM.
OXYGEN SENSOR HEATER, CHECKING
- Z29 = Oxygen Sensor (02S) heater, bank 1.
- Z30 = Oxygen Sensor (02S) 2 heater, bank 2.
- Disconnect heated oxygen sensor harness connector.
- Switch multimeter (Fluke 83 or equivalent) to 20 volt range and connect between terminals 1 (B+) and 2 (GND). See Fig 2 .
- Start engine and let idle.
Specified value: approx. 12-14 volts.
If the specified value is not obtained:
- Check fuse for oxygen sensor heating.
- Check fuel pump relay.
- Check wiring for continuity between terminal 1 and fuse in fuse holder, if necessary check terminal assignments.
Specified value: Max. 1 ohm (ohm)
- Check wiring for continuity between terminals 2 and 8 on ECM connector E.
Specified value: Max. 1 ohm (ohm)
- Check wiring for continuity between terminals 2 and 4 of ECM connector E (02S heater -Z30-).
Specified value: Max. 1 ohm (ohm)
- If the specified value is obtained:
- Switch multimeter (Fluke 83 or equivalent) to measure resistance (ohm) and connect between terminals 1 and 2.
- Specified value (at room temperature): approx. 2-5 ohms (ohm).
If the specified value is not obtained:
- Replace heated oxygen sensor.