LEMON Manuals: Even more car manuals for everyone

Heated O2 Sensor & O2 Sensor Heater Checking (GROUP 24, NO. 96-01)

Publication date: 1996-04-01
Reference number: GROUP 24, NO. 96-01

HEATED O2 SENSOR & O2 SENSOR HEATER CHECKING

HEATED O2 SENSOR & O2 SENSOR HEATER CHECKING

TECHNICAL SERVICE BULLETIN

Reference Number(s): GROUP 24, NO. 96-01

HEATED OXYGEN SENSOR AND OXYGEN SENSOR HEATER AFTER THREE WAY CATALYTIC CONVERTOR, CHECKING

Model(s): 1996-on Audi A6 With OBD II MMS 411 Fuel System

Group: 24 - Multiport Fuel injection

Bulletin No.: 96-01

Date: April 1, 1996

SERVICE INFORMATION

The following repair information has been revised and will be integrated with the next Repair Manual update.

This information replaces pages 24-55 through 24-58 in the current version Repair Manual.

HEATED OXYGEN SENSOR (HO2S) AND OXYGEN SENSOR (02S) HEATER AFTER THREE WAY CATALYTIC CONVERTER (TWC), CHECKING

NOTE:
  • G130 = 02S behind three way catalytic converter, bank 1.
  • G131 = 02S 2 behind three way catalytic converter, bank 2.

- Disconnect connector for 02S behind three way catalytic converter -G130- or -G131-.

- Switch multimeter (Fluke 83 or equivalent) to measure resistance (ohm) and check for continuity between terminal 3 (GND wire) and 4 (signal wire) of heated oxygen sensor. See Fig 1 .

If there is continuity:

- Replace heated oxygen sensor.

If there is not continuity:

- Switch multimeter (Fluke 83 or equivalent) to 2 volt range and connect between terminals 3 (GND) and 4 (signal wire) on harness connector. See Fig 2 .

- Switch ignition ON.

Specified value: 400 +/- 50 mV

If the specified value is not obtained, check wiring to ECM as follows:

- Switch ignition OFF.

- Connect VAG 1598/19 test box to ECM wiring harness.

- Check following wiring connections for continuity. Refer to Fig 3 .

Specified value: Max. 1 ohm (ohm)

OXYGEN SENSOR

Heated Oxygen Sensor Connector Terminal VAG 1598/19 Test Box Socket Number
-G130- 3 C17
4 C20
-G131- 3 C17
4 C21

If the specified value is not obtained:

- Eliminate open or short circuit.

If wiring OK:

- Replace ECM.

OXYGEN SENSOR HEATER, CHECKING

NOTE:
  • Z29 = Oxygen Sensor (02S) heater, bank 1.
  • Z30 = Oxygen Sensor (02S) 2 heater, bank 2.

- Disconnect heated oxygen sensor harness connector.

- Switch multimeter (Fluke 83 or equivalent) to 20 volt range and connect between terminals 1 (B+) and 2 (GND). See Fig 2 .

- Start engine and let idle.

Specified value: approx. 12-14 volts.

If the specified value is not obtained:

- Check fuse for oxygen sensor heating.

- Check fuel pump relay.

- Check wiring for continuity between terminal 1 and fuse in fuse holder, if necessary check terminal assignments.

Specified value: Max. 1 ohm (ohm)

- Check wiring for continuity between terminals 2 and 8 on ECM connector E.

Specified value: Max. 1 ohm (ohm)

- Check wiring for continuity between terminals 2 and 4 of ECM connector E (02S heater -Z30-).

Specified value: Max. 1 ohm (ohm)

- If the specified value is obtained:

- Switch multimeter (Fluke 83 or equivalent) to measure resistance (ohm) and connect between terminals 1 and 2.

- Specified value (at room temperature): approx. 2-5 ohms (ohm).

NOTE: With small increases in temperature, resistance increases sharply and oxygen sensor heater current decreases.

If the specified value is not obtained:

- Replace heated oxygen sensor.

Fig 1: Oxygen Sensor Connector Terminal Designation
G95C55295
Fig 2: Harness Connector Terminal Designation
G95D55296
Fig 3: VAG Test Box Connectors
G95E55297