Air Switch Circuit
- Follow procedure outlined in Air By-pass Circuit in this story to step 4. If air is not being exhausted from base of diverter valve inspect air pump for proper operation.
- If air exhausts from both ports of air switch valve, replace air switch valve and retest system. If air exhausts only from port B, remove vacuum hose and check for vacuum during the first 30 seconds of operation. If no vacuum is present, replace air switch valve and retest. If vacuum is present, test upstream solenoid as described in Computerized Emission Control article in this section.
- If air exhaust from switch valve is normal, see procedure outlined in step 6) of Air By-pass Circuit Test in this article.