DC-DC Converter Circuit Inspection
Preconditions
NOTE: This procedure can be done before any other inspections are completed because this test procedure includes all of the following inspection items. However, if this test fails, it will be necessary to continue with each inspection item individually to determine which item failed.
- External circuit is normal
Test Procedure
- Preparation
-
- -
Alternator connector (1P): disconnected
- -
12 volt battery sensor connector (2P): disconnected
- -
PCM connector A (50P): disconnected
- -
- Procedure
-
- -
Perform the inspection according to the following table.
- -
(Disconnected)Alternator connector (1P)female terminals
IG Mode
Normal Conditions
DC-DC converter internal circuit inspection
OFF
Not shorted
Results
- If it is abnormal, there is a problem with the DC-DC converter.