DTC C1841-11 (42-02): Intersection
Rear Differential Fluid Temperature Sensor Inspection
NOTE: Since there is no direct method to test the component itself, troubleshooting is performed on the related components.
Preconditions
- External circuit is normal.
Test Procedure
SH-AWD control unit output voltage inspection
- Preparation
-
- -
Rear differential fluid temperature sensor 2P connector: disconnected
- -
- Procedure
-
- Turn the vehicle to the ON mode.
- Normal Conditions
-
- -
The HDS [Voltage of the Fluid Temperature Sensor 1 for Rear Differential] value is more than 0.15 V .
- -
Results
- If it is normal, there is a failure with the rear differential fluid temperature sensor.
- If it is abnormal, there is a problem with the related components.
SHAWD_TOH Shorted Wire Inspection
Test Procedure
- Preparation
-
- -
Rear differential fluid temperature sensor 2P connector: disconnected
- -
SH-AWD control unit 24P connector: disconnected
- -
- Procedure
-
- -
Perform the inspection according to the following table.
NOTE: Refer to the Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances.
- -
| (Disconnected) Rear differential fluid temperature sensor 2P connector female terminals |
| IG Mode |
|
Normal Conditions | ||
| SHAWD_TOH shorted to ground inspection | OFF | Not shorted | ||
Results
- If abnormal, there is a problem in the circuit.
SH-AWD Control Unit Inspection
Test Procedure
- If the other inspection item(s) indicated a normal condition, then it is determined that the remaining SH-AWD control unit is the cause.
Results
- There is a problem with the SH-AWD control unit.