DTC C1120-14: Inspection
SW1, SW3, SW4, SW6 Circuit Inspection
Test Procedure
- Preparation
-
- -
VSA modulator-control unit 46P connector: disconnected
- -
Electric parking brake switch 12P connector: disconnected
- -
- Procedure
-
- -
Perform the inspection according to the following table.
- -
| (Disconnected)VSA modulator-control unit 46P connector emale terminals | (Disconnected) Electric parking brake switch 12P connector female terminals | ||||
| IG Mode |
|
|
Normal Conditions | ||
| SW1 open wire inspection | OFF | There is less than 1 Ohm | |||
| SW3 open wire inspection | OFF | There is less than 1 Ohm | |||
| SW4 open wire inspection | OFF | There is less than 1 Ohm | |||
| SW6 open wire inspection | OFF | There is less than 1 Ohm | |||
| NOTE: Refer to the Open/Shorted Wire Inspection Description for the method to inspect the shorted circuit below, then start to inspect according to circumstances. | |||||
| SW1 shorted to ground inspection | OFF | Not shorted | |||
| SW3 shorted to ground inspection | OFF | Not shorted | |||
| SW4 shorted to ground inspection | OFF | Not shorted | |||
| SW6 shorted to ground inspection | OFF | Not shorted | |||
Results
- If abnormal, there is a problem in the circuit.
VSA Modulator-Control Unit Inspection
Test Procedure
- If the other inspection item(s) indicated a normal condition, then it is determined that the remaining VSA modulator-control unit is the cause.
Results
- There is a problem with the VSA modulator-control unit.