DTC C1100-94: Inspection
Left Rear Electric Parking Brake Actuator Inspection
NOTE: Since there is no direct method to test the inspection item, troubleshooting is performed using a known-good component.
Test Procedure
- Install a known-good left rear electric parking brake actuator and attempt to reproduce the failure.
Results
- If the failure is reproduced, there is a problem with other related components.
- If the symptom/DTC goes away, the left rear electric parking brake actuator must be faulty.
Right Rear Electric Parking Brake Actuator Inspection
NOTE: Since there is no direct method to test the inspection item, troubleshooting is performed using a known-good component.
Test Procedure
- Install a known-good right rear electric parking brake actuator and attempt to reproduce the failure.
Results
- If the failure is reproduced, there is a problem with other related components.
- If the symptom/DTC goes away, the right rear electric parking brake actuator must be faulty.
VSA Modulator-Control Unit Inspection
Test Procedure
- If the other inspection item(s) indicated a normal condition, then it is determined that the remaining VSA modulator-control unit is the cause.
Results
- There is a problem with the VSA modulator-control unit.