LEMON Manuals: Even more car manuals for everyone

Valve Clearance Adjustment

WARNING: This page is about a different variant/trim than selected.
CAUTION: Always rotate engine in direction of normal rotation(counterclockwise as viewed from front of engine). Backward rotation may cause timing belt to jump time.
  1. Adjust valves when engine temperature is 100°F (38°C) or less. Remove valve cover. Rotate crankshaft counterclockwise until No. 1 piston is at TDC of compression stroke.
  2. Ensure UP marks on camshaft sprockets are at top, and TDC grooves on pulleys are aligned with TDC groove on back cover. See Fig 1 . Adjust clearance on both valves for No. 1 cylinder. Loosen lock nuts, and turn adjustment screw until clearance is as specified. Tighten lock nut to 18 ft. lbs. (25 N.m). Recheck adjustment. See VALVE CLEARANCE SPECIFICATIONS table.
  3. Rotate crankshaft 180 degrees counterclockwise (camshaft sprockets turn 90 degrees) so No. 3 piston is at TDC of compression stroke. UP marks should point to exhaust side. Adjust clearance on both valves for No. 3 cylinder.
  4. Rotate crankshaft 180 degrees counterclockwise so No. 4 piston is at TDC of compression stroke. Ensure UP marks are pointing down. Adjust clearance on both valves for No. 4 cylinder.
  5. Rotate crankshaft 180 degrees counterclockwise so No. 2 piston is at TDC of compression stroke. Ensure UP marks are pointing to intake side. Adjust clearances on both valves for No. 2 cylinder. Install new valve cover gasket. Install valve cover. Retighten crankshaft pulley bolt to 133 ft. lbs. (180 N.m).
Fig 1: Positioning Camshafts For Valve Adjustment
G91C01406Courtesy of AMERICAN HONDA MOTOR CO., INC.
VALVE CLEARANCE SPECIFICATIONS

Application In. (mm)
Exhaust 0.006-0.008 (0.16-0.20)
Intake 0.003-0.005 (0.08-0.12)